Dental Manufaktur
Dental technology from HERRLAN includes specialised products for dental model fabrication. The focus is on the HERRLAN-PSM precision die model technique with coordinated die materials, catalysts, dowel pins and additional accessories.
Discover PSM I and PSM II for different impression materials as well as supplementary dental products and accessories for dental processing.
HERRLAN-PSM for dental model fabrication
The HERRLAN-PSM system was developed for the production of precision die models in crown, bridge and combination techniques. The system includes coordinated materials and accessories for the individual steps of model fabrication.
With PSM I and PSM II , different product versions are available. Which version is used depends, among other things, on the impression material used.
PSM I & PSM II – matched to the impression material
HERRLAN PSM I is intended for processing based on silicone impression materials. The system includes, among other things, PSM I die material and the corresponding PSM I catalyst.
For impressions based on polyether , the PSM II system is used. HERRLAN points out that polyether impressions must be neutralised with IsoPe before model fabrication and then processed with PSM II.
Die material, catalysts & dowel pins
Various components coordinated with the system are available for working with the HERRLAN-PSM technique:
- PSM I die material for silicone impression materials
- PSM I catalyst
- PSM II die material for polyether impression materials
- PSM II catalyst
- IsoPe for neutralising polyether impression materials
- PSM dowel pins with and without insert pin
- Dowel pin finder as an accessory for model fabrication
by Master Dental Technician J. Herrmann
for efficient model fabrication
|
HERRLAN - PSM
Die Model Technique
|
HERRLAN - ADR
Distortion-free impressions
|
HERRLAN - PSM
Saw / Lamella Technique
|
HERRLAN - PSM I & II
Precision Die Model Technique
by Master Dental Technician J. Herrmann
1. Working with the HERRLAN-PSM I & II system
2. Mixing the HERRLAN-PSM die material
3. Filling in the PSM material
4. Inserting the PSM dowel pins
5. Blocking out undercut areas in the impression
6. Pouring the impression
7. Removing the PSM dies
8. Finishing the PSM dies
9. Jacket crowns and post teeth
Physical data:
| 1. Mixing ratio 2. Viscosity 3. Working time 4. Setting time 5. Compressive strength 6. Tensile strength 7. Flexural strength 8. Temperature stability 9. Expansion 10. Contraction |
Catalyst : powder 1 : 2-3 500 - 800 cp approx. 5 - 7 minutes at 22° C. approx. 15 minutes at 22° C. 19,60 kgf/mm² 9,00 kgf/mm² 10,02 kgf/mm² 175,0° C. 0 (measured on silicone, polyether & hydrocolloid 0 -surfaces with layer thicknesses below 10 mm) |
1. Working with the HERRLAN-PSM I system:
using the PSM dowel pins with insert pin and shortened retention section on the basis of silicone impression materials.
C A U T I O N:
Impressions based on polyether rubber must be neutralised with IsoPe before model fabrication and processed with PSM II.
Thoroughly clean the impression of blood, grease and saliva residues using a cleaning agent.
If the impression contains areas that are difficult to see, the margin in the vestibular area of the dies may be trimmed back, provided it is not required for the dental restoration to be fabricated.
2. Mixing the HERRLAN-PSM die material:
Mix the die material in a flexible container by volume as follows:
1 part catalyst : 2 - 3 parts powder
Place the required amount of catalyst for mixing 2 - 3 dies in a Resi-Mix cup (Fig. 1) and mix while adding small quantities of powder several times (Fig. 2).
![]() Fig. 1 |
If too much powder is
used, the material hardens too early. The PSM material should be mixed in the same way as a conventional autopolymerising material. |
Fig. 2 |
Please note that the PSM material has a working time of 5 - 7 min. at 22° C. and a setting time of 15 min.
Always store HERRLAN-PSM carefully protected from heat and light.
We recommend storage in a refrigerator.
3. Filling in the PSM material:
Pour or place the PSM material bubble-free with a drop instrument into the die negatives of the impression up to the level of the cervical margin (Fig. 3 & 5 ).
Fill repeatedly in portions using the drop instrument
(Fig. 4) until the die lumen is completely filled (Fig. 5).
![]() Fig. 3 |
![]() Fig. 4 |
Fig. 5 |
4. Inserting the PSM dowel pins:
The dowel pins must be inserted centrally immediately after filling the die and aligned parallel by eye (Fig. 6 & 7).
![]() Fig. 6 |
![]() Fig. 7 |
C A U T I O N:
If the PSM material becomes too viscous during processing, you have one single opportunity to add PSM catalyst and remix the material.
- This procedure extends the working and setting time. -
Do not repeat this process several times under any circumstances, otherwise the PSM material will no longer cure completely and its dimensional accuracy can no longer be guaranteed.
When using the HERRLAN-PSM system, the gingival margin of the model remains completely intact.
In this context, note that the dowel pins should be aligned as centrally as possible in the dental arch area, insofar as the required pin parallelisation permits this (Fig. 7 & 8).
After the PSM material has hardened, new PSM material is built up conically on its base surface in a pyramid shape from the cervical margin towards the dowel pin (Fig. 7 & 8).
I M P O R T A N T:
The retention section and shaft base of the dowel pin must be completely embedded in the PSM material and must no longer be visible (Fig. 8).
![]() Fig. 8 |
Fig. 9 |
The most important aspect of this work step is to build up the die base surfaces as smoothly and conically as possible while avoiding undercut areas (Fig. 9).
C A U T I O N:
Under no circumstances may the dies be removed from the impression before pouring with model plaster (no repositioning) !!!!
5. Blocking out undercut areas in the impression:
After all dies have been filled, built up conically and cured, any undercut areas in the cervical region of the impression should be blocked out (Fig. 10).
The retraction cord effect can cause undercut cervical margin areas to form (Fig. 10).
![]() Fig. 10 |
![]() Fig. 11 |
Fig. 12 |
These must be eliminated by blocking out (PSM blocker).
Otherwise, these undercut cervical margins could break off later when the dies are pressed out of the finished model.
For this you need a scalpel and the PSM blocker. The visibly undercut areas in the impression are parallelised by eye (Fig. 11, 12 & 13), and then the
dowel pin finders are carefully placed onto the ends of the dowel pins and aligned vestibularly like small flags (Fig. 14 ).
Fig. 13 |
![]() Fig. 14 |
6. Pouring the impression:
The impression can now be poured immediately without isolating the surfaces of the dies, the dowel pins or the finders.
7. Removing the dies:
After the base material has set and the model has been demoulded, trim the model base laterally until the dowel pin finders are visible as red rectangles in the base (Fig. 15 & 16).
The insert pins of the dowel pins are then removed. The upper and lower jaw models are then placed in articulation (Fig. 15), and only then are the red finders easily levered out of the base with a pointed tool (e.g. graver or triangular tool) (Fig. 16).
![]() Fig. 15 |
Fig. 16 |
In the resulting chambers, the shaft ends of the pins are visibly exposed (Fig. 17 & 18), and the dies can now be removed from the dental arch by applying light pressure beneath the pin with a small screwdriver (Fig. 19).
![]() Fig. 17 |
![]() Fig. 18 |
Fig. 19 |
Twisting during reinsertion is prevented by the lateral flat grinding of the dowel pins and by the individual conical die base
(Fig. 20 & 21).
![]() Fig. 20 |
Fig. 21 |
To remove the dies from the model, the model no longer needs to be removed from the articulator because the pin ends are accessible from the side (Fig. 15 & 19) !
![]() Fig. 15 |
Fig. 19 |
8. Finishing the PSM dies:
To facilitate checking the crown margin during modelling or ceramic layering, remove any interfering areas (Fig. 21) below the preparation margin with a tungsten carbide bur.
Fig. 21 |
C A U T I O N:
Only work on the outer marginal areas of the die base (pyramid).
The central part of the pyramid-shaped die base around the pin should remain in the model to provide additional security for the vertical positional stability of the die!
Because the PSM material reproduces the tooth die with dimensional accuracy, i.e. there is no expansion as with gypsum-based materials, now apply a die spacer (minimum layer thickness approx. 0,10 - 0,3 mm) to the dies to simulate the cement gap, with the coating ending approx. 0,05 - 1 mm above the preparation margin in order to guarantee an exact marginal seal when the finished restoration is fitted.
For new users who have previously fabricated their work using pure plaster models, it should be emphasised once again at this point that the no-longer-present expansion of the plaster and the contraction of the impression material must be taken into account when determining the thickness of the coating (as these parameters cannot be described, please contact the manufacturers of these materials for the relevant values); otherwise, the finished restoration will feel too “tight” when fitted because the excess dental cement cannot drain away completely due to the now exact marginal seal.
9. Jacket crowns and post teeth:
For jacket crowns and post teeth, follow the instructions up to point 3. Inserting the PSM dowel pins. After filling the jacket and/or post die negatives of the impression with PSM material up to the cervical margin and placing the dowel pin, allow the PSM material to cure completely.
Then cut PSM separating lamellae to size (Fig. 22) and insert them into the impression as shown in Fig. 23 as partitions for the required die base or dental arch section.
![]() Fig. 22 |
![]() Fig. 23 |
![]() Fig. 24 |
Place separating lamellae convergently (as when making saw cuts) !
The dental arch area between the partitions is poured with PSM material (Fig. 13 & 24); after curing, the finders are fitted (Fig. 14) and work continues with point 5. Pouring the impression. By using PSM separating lamellae made of torsion-resistant stainless steel, considerably finer model cuts are obtained compared with conventional saw-cut techniques
(Fig. 25 & 26 ).
Fig. 25
|
Fig. 26
|
PSM I, PSM II, IsoPe, dowel pins, dowel pin finders, mouthwashes and hydrogen peroxides are custom-made products that are only formulated or manufactured after your order with regard to the required intended use, so that the legal properties and the stated best-before date are guaranteed at the time of dispatch, and they are excluded from returns.